0
(0)

Daikin CHPT/CHPTA Horizontal “A” Cased Coil

The Daikin CHPT/CHPTA series is a premium indoor evaporator coil cabinet designed specifically for horizontal (“A” orientation) airflow configurations—perfect for attics, crawl spaces or large-return duct setups. It features an all-aluminum evaporator coil, factory-installed thermal expansion valve (TXV) for cooling and heat pump applications, and a durable horizontal-cabinet design. At TopCare HVAC of Oakville, we assist with correct system matching, professional installation, annual maintenance and warranty registration to ensure your CHPT/CHPTA system runs reliably for years.

Technical Specifications (Selected)

Here’s a summary of important published specs for the CHPT/CHPTA series:

SpecificationDetail / Notes
Cabinet OrientationHorizontal “A” (airflow side-to-side)
Refrigerant TypeR-410A for standard models; some documentation notes R-32-compatible variants for CAPTA/CHPTA.
Coil ConstructionAll-aluminum tubing & fins.
Installed Expansion DeviceFactory-installed TXV (cooling & heat pump applications)
Cabinet DepthApprox. 21″ for easier attic/tight-space access.
Warranty12-Year Parts Limited Warranty (registration and annual maintenance required)
Daikin CHPT/CHPTA Horizontal “A” Cased Coil 1

Features & Benefits

Here are the key features of the CHPT/CHPTA (with relevant SEO/LSI keywords like “horizontal A coil”, “cased evaporator coil”, “all-aluminum coil”, “factory TXV indoor coil”) and how they benefit your clients:

  • Internal Factory‐Installed TXV for Cooling & Heat Pump Use
    The CHPT/CHPTA models include a built-in thermal expansion valve, simplifying installation and optimizing refrigerant control for matched outdoor units.

  • All-Aluminum Evaporator Coil
    The coil uses aluminum tubing and fins throughout, offering enhanced corrosion resistance and durability compared to older mixed-metal designs.

  • Horizontal “A” Cased Cabinet Design
    Built for horizontal airflow (side-to-side) orientation, making it ideal for attic or crawl-space installations where vertical duct routing is impractical.

  • 21″ Depth & Service-Friendly Cabinet
    Many models support a 21-inch nominal cabinet depth for easier attic or tight-space access, foil-faced insulation to reduce condensation, rust-resistant thermoplastic drain pans, and front access panels (on CHPTA) for maintenance convenience.

  • Check Flowrater & Rifled Aluminum Tubing
    The series includes “Check Flowrater” metering (for cooling & heat-pump applications) and rifled aluminum tubing with corrugated aluminum fins—designed to improve performance and durability.

  • Durable Cabinet & Finishes
    Features include galvanized steel cabinet with leather-grain embossing, foil-faced insulation, and thermoplastic drain pans with secondary drains. These features support longer life and better performance in challenging environments.

Warranty & Registration

  • The CHPT/CHPTA series is backed by a 12-Year Parts Limited Warranty, provided the unit is installed by a certified contractor, registered online (within 60 days in most regions) and annual professional maintenance is performed.

  • At TopCare HVAC of Oakville, we handle warranty registration and ensure your installation meets all manufacturer and regional requirements, giving you peace of mind.


Installation, Maintenance & Repair (Oakville)

Professional Installation:

  • We begin with accurate heating & cooling load calculations to ensure correct coil size and match with the outdoor unit.

  • Install the CHPT/CHPTA coil in the correct horizontal orientation (type “A” airflow), ensure proper return and supply duct alignment, clearances and cabinet orientation.

  • Connect refrigerant lines, install condensate drain pans and lines, ensure mechanical access, seal cabinet and ducts per code.

  • Commission the system: verify airflow, refrigerant metering (TXV), and performance of indoor coil and matched outdoor unit.

Preventive Maintenance:

  • At least once annually (or more often in homes with high usage, pets, heavy dust or attic installations):

    • Replace or clean air filters

    • Inspect coil surface for dust/debris, clean as necessary

    • Check drain pan and condensate lines for blockage or overflow

    • Inspect cabinet for insulation damage, condensation or air-leaks

    • Verify matched outdoor unit performance, check for fault codes (if system is communicating)

Repairs & Troubleshooting:

  • Diagnose issues such as low cooling capacity, icing, high superheat, low airflow: check TXV operation, airflow, coil cleanliness and match with outdoor unit.

  • Inspect cabinet/drain pan for water leaks or corrosion (especially in attic installations).

  • Use genuine Daikin parts and adhere to manufacturer service protocols to preserve performance and warranty.


Frequently Asked Questions (FAQs)

Q: What does “horizontal ‘A’ coil” mean for CHPT/CHPTA?
A: “Horizontal ‘A’” refers to side-to-side airflow in a cased coil cabinet, as opposed to up-flow or down-flow models. It’s designed where vertical duct routing is not suitable.

Q: Why should I pick an all-aluminum evaporator coil?
A: All-aluminum coils offer improved corrosion resistance, lighter weight and potential longer lifespan, especially useful in high-humidity, attic or coastal installations.

Q: Can this coil be used with a heat pump system?
A: Yes—since the CHPT/CHPTA includes factory TXV metering and is designed for both cooling and heat-pump applications when matched correctly.

Q: How often should the coil be serviced to keep warranty valid?
A: At minimum once per year; more frequent maintenance may be required in homes with pets, heavy dust, attic usage or humid environments. Correct maintenance preserves performance and warranty coverage.


Why Choose TopCare HVAC for Your CHPT/CHPTA Installation

  • We are certified Daikin installers experienced with indoor coils, horizontal-cabinet installations, and full system matching (indoor coil + outdoor unit + ducts).

  • Serving Oakville, Burlington, Milton, Mississauga and surrounding areas—local expertise, responsive service.

  • Transparent pricing, full lifecycle service—from equipment selection, installation, maintenance to warranty registration.

  • We provide maintenance plans and help you maintain your system for efficiency, reliability and long-term comfort.


Ready to install the Daikin CHPT/CHPTA Cased Horizontal “A” Coil?

Contact TopCare HVAC of Oakville today for a free quote, home assessment or to schedule your installation or service. We’ll assist you in selecting the right model, ensuring proper matching, installing it professionally, and providing ongoing support for efficient, reliable indoor comfort.

AWST (R-32)
AWST (R-32)
AMST (R-32)
AMST (R-32)
DFVE (R-32)
DFVE (R-32)
115V DFVE (R-32)
115V DFVE (R-32)
DMVT (R-32)
DMVT (R-32)
ACST Series (R-32)
ACST Series (R-32)
115V DFVE
115V DFVE
ACNF Ceiling Mount
ACNF Ceiling Mount
ACSF Ceiling Mount
ACSF Ceiling Mount
AMST
AMST
ARUF
ARUF
ASPT
ASPT
AWSF Wall Mount
AWSF Wall Mount
AWST Wall Mount
AWST Wall Mount
AWUF/AWUT Wall Mount
AWUF/AWUT Wall Mount
DFVE
DFVE
DMVE
DMVE
DMVT
DMVT
DVFEC
DVFEC
DVPEC
DVPEC
DVPTC
DVPTC
CAHEA R-32
CAHEA R-32
CAPE/CAPEA
CAPE/CAPEA
CAPE/CAPEA R-32
CAPE/CAPEA R-32
CAPF/CAPFA
CAPF/CAPFA
CAPFA R-32
CAPFA R-32
CAPTA R-32
CAPTA R-32
CAUF/CAUFA
CAUF/CAUFA
CAUTA R-32
CAUTA R-32
CHPE
CHPE
CHPEA R-32
CHPEA R-32
CHPF
CHPF
CHPT/CHPTA
CHPT/CHPTA
CHPTA (R-32)
CHPTA (R-32)
CSCF
CSCF
CSCT R-32
CSCT R-32
MBVC Modular Blower
MBVC Modular Blower
MBVK Modular Blower
MBVK Modular Blower

Please rate our website

Let us improve this!

Tell us how we can improve?